Load recator CNW M 854

Reduce voltage rise (< 200V / µs) and distortions – optimally protect electrical consumers.

du/dt choke CNW M 833

Fully encapsulated three-phase dv/dt Filter (IP20) Description Reduce voltage rise to < 500V / µs – protect electrical loads and insulation cost-effectively. A simple and inexpensive method of reducing the rate of voltage rise is to use a du / dt filter. The filter dampens the voltage rise to acceptable values and prevents overvoltages on long supply lines. Losses and heating are minimised and the leakage current is reduced. By limiting the voltage gradient, the motor insulation is protected and the service life is extended. EMC interference in the radiation range from 1 MHz to 30 MHz is also reduced. Voltage rises are reduced to < 500V / µs. Advantages Optimal mechanical protection of the reactor Optimal mechanical protection of the choke Protection for electrical consumers Limit the voltage rise to <500V/µs Extended service life of electrical consumers Low leakage currents on the motor Reduced losses Very low noise Easy construction Production possible according to UL insulation system E251513 Typical applications Drive systems for motor drives: Mechanical engineering, Elevators / escalators, Pipes, Conveyor technology, Ventilation and air conditioning, Robotics, Automation technology, Power supplies and Wind turbines Technical specification Type Protection class Nominal voltage[V] Rated current[A] Inductance[mH] Capacity[pF] Weight[kg] Clamp[mm²] Cable gland CNW M 833 / 8 Protection class up to IP 66 3 x 400 ≥ 60 Hz 8 2 330 3,3 2,5 M20x1,5 CNW M 833 / 16 Protection class up to IP 66 16 0,9 330 4,5 6 M25x1,5 CNW M 833 / 36 IP 65 36 0,42 1500 9 16 M32x1,5 CNW M 833 / 60 IP 65 60 0,27 2200 25 35 M40x1,5 CNW M 833 / 90 IP 65 90 0,17 4700 27 35 M40x1,5 CNW M 833 / 180 IP 65 175 0,09 10000 40 95 M63x1,5 DIMENSIONS IN MM Type Dimensions L1 [mm] L2 [mm] L3 [mm] B1 [mm] B2 [mm] B3 [mm] B4 [mm] B5 [mm] H1 [mm] H2 [mm] H3 [mm] N1 [mm] N2 [mm] D [mm] CNW M 833 / 8 170 140 150 80 80 55 20,5 5,5 170 57 75 135 65 5,5×7 CNW M 833 / 16 180 140 170 85 80 65 10,5 5,5 170 57 75 155 70 5,5×7 CNW M 833 / 36 245 175 175 115 120 80 20 20 250 140 110 155 95 5,5×15 CNW M 833 / 60 315 249 255 180 175 120 30 27 323 218 105 185 150 9×13 CNW M 833 / 90 315 250 255 180 175 120 30 25 325 218 105 185 150 9×13 CNW M 833 / 180 355 270 – 127 200 160 105 8 350 220 130 185 105 10×18 Data sheet Download our extensive catalog and discover many other REO products. Download Data sheet Certifications

Choke NTT LD-DH 100

Directly cooled surge current choke Description The short-circuit current limiting choke is used to limit the short-circuit current in the event of a bridge short-circuit. This protects the intermediate circuit and prevents destruction of the IGBT. Advantages Less copper Small dimensions compared to traditional cooling methods Significantly lower weight Cooling with water/glycol High protection class Suitable for high pulse current Technical specification According to: EN 60076-6 Test voltage: 12kV Overload: 1,5 x INenn 1 min / h Climatic category: DIN IEC 68 Part 1 25/085/21 Nominal Voltage: 3000 V Rated current: 500 – 2500 A

Test Choke RPD 9039

Three-phase load reactor Description Drive inverters or output filters must be tested at rated current by using typically motor-generators. Due to the high costs, the specimens can be loaded alternatively with chokes which have a sufficient linearity and does not exceed the temperature limit at higher frequencies. Advantages Small dimensions Cost-effective solution Technical specification Cooling: AN Insulation class F Climatic category: 25/085/21 DIN IEC 68 Part 1 Max. winding temperature: 140 °C Protection rating: IP 00 Rated voltage : 400 V Rated current : 0,6 – 75 A Inductance : 3,15 – 254 mH Type Rated voltage [V] Rated current [A] Inductance [mH] DC-Resistance [mΩ] Power loss [W] RPD 9039/0,6 3 x 400 0,6 254 6009,2 20 RPD 9039/7,0 3 x 400 7 31,4 221,7 70 RPD 9039/32,0 3 x 400 32 8,550 34,3 230 RPD 9039/75,0 3 x 400 75 3,150 12,6 430 Dimensions in mm Type L [mm] B [mm] H [mm] N1 [mm] N2 [mm] øD1 [mm] øD1 [mm] A1 [mm] Cooper [kg] Weight [kg] RPD 9039/0,6 125 91 85 100 52 5 x 8 9 33,1 1 2 RPD 9039/7,0 190 123 157 170 79 8 x 12 9 34,5 3 10 RPD 9039/32,0 300 168 264 224 120 10 x 18 9 34,7 11 38 RPD 9039/75,0 360 182 313 264 142 10 x 18 9 35,7 18 58

Test reactor NPT 8929

Single-phase test reactor Description These reactors are used in test laboratories as load reactor. They can be interconnected with each other. If these reactors used with appropriate resistors, a test under different cos (phi) is possible. Advantages Robust design High flexibility compact construction Low losses Technical specification Insulation class: F at 40° C Climatic category: 25/085/21 DIN IEC 68 Part 1 Max. winding temperature: 125° C Protection rating: IP00 Nominal Voltage: 230 V Rated current: 0,5 – 32,5 A Inductance: 0,127 – 3180 mH Type Rated voltage [V] Rated current [A] Inductance [mH] DC-Resistance [mΩ] Power loss [W] NPT 8929 / 0,5 230 0,5 3180 55670,2 23 NPT 8929 / 1,25 230 1,25 1270 16880,0 43 NPT 8929 / 1,66 230 1,66 955 9977, 8 47 NPT 8929 / 2,5 230 2,5 636 6388,5 66 NPT 8929 / 5 230 5,0 318 1782,5 94 NPT 8929 / 32,5 230 32,5 0,318 0,0 39 NPT 8929 / 32,5 230 32,5 0,127 7,0 13 NPT 8929 / 32,5 230 32,5 0,318 0,0 27 Dimensions in mm Type L [mm] B [mm] H [mm] N1 [mm] N2 [mm] øD1 [mm] Connection [mm²] Cooper [kg] Weight [kg] NPT 8929 / 0,5 120 96 205 76 77 7 x 13 2,5 0,7 5 NPT 8929 / 1,25 160 105 265 100 81 7 x 13 2,5 2 9,8 NPT 8929 / 1,66 160 115 270 100 91 7 x 13 2,5 3,1 12,2 NPT 8929 / 2,5 200 122 310 124 94 10 x 18 4 3,9 17 NPT 8929 / 5 240 153 355 144 125 10 x 18 4 7,3 29 NPT 8929 / 32,5 120 96 208 76 77 7 x 13 16 0,84 6,5 NPT 8929 / 32,5 100 82 190 63 65 6 x 10 16 0,44 3,6 NPT 8929 / 32,5 120 96 208 76 77 7 x 13 16 0,94 6,5

Harmonic Filter CNW 999

Compensating choke (7 or 14% detuning factor) Description Reactive Power and harmonics compensation equipment; Protection of capacitors Advantages Low inductance tolerance Low-noise Linear behaviour even with current higher than rated current Connection on terminals or wire at the option Technical specification Conforming to: DIN EN 61558-2-20 Test voltage: L-L 2100 V, DC 1 min L-PE 2700 V, DC 1 min Overload: 1,5 x INenn 1 min / h Climatic category: DIN IEC 60068-1 Thermal class: H Protection rating: IP00 Output voltage : 25 – 600 V Output current : 2 – 600 A Output power : 1000 – 15000 W Input voltage switchable [V] V   Type Detuning factor 7% Reactive power capacitors [kVAr] Resonant frequency [Hz] Detuning factor (p) [%] Rated current [A] Current @ 50Hz [A] Inductance per strand [mH] Cooper [kg] Weight [kg] CNW 999/10/6 6,25 189 7 10,6 10,0 6,0 3 8 CNW 999/19/3 12,5 189 7 20,5 19,0 3,0 4 9 CNW 999/38/1,53 25 189 7 41,0 38,0 1,53 1 17 CNW 999/75/0,78 50 189 7 80,0 75,0 0,78 1 28 Type Detuning factor 14% Reactive power capacitors [kVAr] Resonant frequency [Hz] Detuning factor (p) [%] Rated current [A] Current @ 50Hz [A] Inductance per strand [mH] Cooper [kg] Weight [kg] CNW 999/9/14,5 6,25 134 14 9,1 9,0 14,5 5 9 CNW 999/19/6,9 12,5 134 14 19,1 19,0 6,9 5 15 CNW 999/38/3,5 25 134 14 38,2 38,0 3,5 1 24 CNW 999/76/1,73 50 134 14 76,5 76,0 1,73 1 43 DIMENSIONS IN MM Type Detuning factor 7% L [mm] B [mm] H [mm] N1 [mm] N2 [mm] D1 [mm] D2 [mm] Distance [mm] Weight [kg] CNW 999/10/6 190 101 155 170 69 8×12 – 30 7 CNW 999/19/3 190 111 155 170 79 8×12 – 30 8 CNW 999/38/1,53 240 150 205 185 97 10×18 9 55 17 CNW 999/75/0,78 265 172 225 200 122 10×18 9 55 28 Type Detuning factor 14% L [mm] B [mm] H [mm] N1 [mm] N2 [mm] D1 [mm] D2 [mm] Distance [mm] Weight [kg] CNW 999/9/14,5 190 97 157 170 69 8×12 – 30 9 CNW 999/19/6,9 240 111 209 185 88 8×12 – 45 15 CNW 999/38/3,5 265 265 225 200 104 10×18 9 55 24 CNW 999/76/1,73 300 197 225 224 144 10×18 9 65 43

Air Choke Ld 220

Air choke with aluminium copper/disc winding Description Air reactors are used when a particularly high linearity is required. By its relatively simple structure, they are not only compact, but also very stable. With our expertise, REO air chokes maintain their full functionality even under extreme conditions. With our expertise, the REO air reactors perform to the required standard, even in the most arduous conditions. REO Mix & Match principle With REO Mix & Match you can choose from a wide range of of options – combine the various options in order to always get the best product for your application. REO is able to offer different designs and winding techniques, a variety of conductor materials and structures. Depending on the specific requirements, we are able to produce an optimal solution by combining these parameters to provide the perfect solution. Optional Layer winding/Disc winding Aluminium, Copper or aluminium + copper Protections: Paint coating, protective coating, housing or REO Xtreme Cooling fan/unit Sensors: Switch NO / NC, PT100, NTC, PTC Advantages No saturation Wide range of material selection Special protective coating High linearity L (i) Very good mechanical strength No hysteresis Optimal weight by forced air cooling Directional air flow through GRP conduits Very efficient liquid cooling option (waveguide) Can be used almost anywhere PTC Technical specification Frequency of the current: DC and AC Tolerances: + 10 / – 10 %, + 5 / – 5 % Taps: By default, no taps (available on request) Insulation: F or H Cooling method and cooling liquid according to IEC 60310: AN, AF or WF Test voltage: up to 12kV 60s 50Hz, up to 25kV 1,2/50µs Mounting: Suspended, vertical or horizontal Mechanical strength, mechanical simulation (FEM): EN 12663 Shock – and vibration stress: IEC 61373 Kat. 1 Kl. B Rated current: 200 – 700 A Inductance: 0,5 – 4 mH Type Inductance (mH) Cooling 3 m/s Cooling 5 m/s Cooling 8 m/s I [A] magn. Energy [J] P [kVA] at 20°C I [A] magn. Energy [J] P [kVA] at 20°C I [A] magn. Energy [J] P [kVA] at 20°C LD 220/200/0,5 0,5 200 10 0,7 250 15,6 1,1 300 22,5 1,6 LD 220/400/0,5 0,5 400 40 1,8 500 62,5 2,9 600 90 4,2 LD 220/700/0,5 0,5 700 122,5 2,4 500 62,5 2,9 600 90 4,2 LD 220/200/1 1 200 20 1,1 250 31,3 1,7 300 45 2,4 LD 220/400/1 1 400 80 2,8 500 125 4,4 600 180 6,3 LD 220/700/1 1 700 245 3,8 850 361,3 5,5 100 5 7,7 LD 220/200/2 2 200 40 1,7 250 62,5 2,6 300 90 3,7 LD 220/400/2 2 400 160 4,4 500 250 6,9 600 360 10 LD 220/700/2 2 700 490 5,7 850 722,5 8,4 1000 1000 11,6 LD 220/200/4 4 200 80 2,5 250 125 3,9 300 180 5,6 LD 220/400/4 4 400 320 6,9 500 500 10,8 600 720 15,6 LD 220/700/4 4 700 980 8,7 850 1445 12,8 1000 2000 17,7 Dimensions in mm Type B [mm] H [mm] T [mm] Cooper [kg] Weight [g] LD 220/200/0,5 250 250 180 11,4 16 LD 220/400/0,5 350 350 180 20,9 29 LD 220/700/0,5 400 400 370 74,8 86 LD 220/200/1 300 300 220 17,6 33 LD 220/400/1 400 400 220 32,5 37 LD 220/700/1 400 400 450 116 124 LD 220/200/2 350 350 230 26,7 40 LD 220/400/2 400 400 310 51,4 87 LD 220/700/2 450 450 490 175 182 LD 220/200/4 400 400 250 40,2 54 LD 220/400/4 420 420 400 80,3 97 LD 220/700/4 500 500 570 267 301

Air reactor LD 210

Air reactor with aluminum/disc winding Description Air reactors are used when a particularly high linearity is required. By its relatively simple structure, they are not only compact, but also very stable. With our expertise, REO air chokes maintain their full functionality even under extreme conditions. With our expertise, the REO air reactors perform to the required standard, even in the most arduous conditions. REO Mix & Match principle With REO Mix & Match you can choose from a wide range of of options – combine the various options in order to always get the best product for your application. REO is able to offer different designs and winding techniques, a variety of conductor materials and structures. Depending on the specific requirements, we are able to produce an optimal solution by combining these parameters to provide the perfect solution. Optional Layer winding/Disc winding Aluminium, Copper or aluminium + copper Protections: Paint coating, protective coating, housing or REO Xtreme Cooling fan/unit Sensors: Switch NO / NC, PT100, NTC, PTC Advantages No saturation Wide range of material selection Special protective coating High linearity L (i) Very good mechanical strength No hysteresis Optimal weight by forced air cooling Directional air flow through GRP conduits Very efficient liquid cooling option (waveguide) Able to be universally applied. Technical specification Frequency of the current: DC and AC Tolerances: + 10 / – 10 %, + 5 / – 5 % Taps: By default, no taps (available on request) Insulation: F or H Cooling method and cooling liquid according to IEC 60310: AN, AF or WF Test voltage: up to 12kV 60s 50Hz, up to 25kV 1,2/50µs Mounting: Suspended, vertical or horizontal Mechanical strength, mechanical simulation (FEM): EN 12663 Shock – and vibration stress: IEC 61373 Kat. 1 Kl. B Rated current: 100 – 700 A   Type Inductance [mH] Cooling 3 m/s Cooling 5 m/s Cooling 8 m/s I [A] magn. Energy [J] P [kVA] at 20°C I [A] magn. Energy [J] P [kVA] at 20°C I [A] magn. Energy [J] P [kVA] at 20°C LD 210/100/1 1 100 5 0,5 140 9,8 0,9 180 16,2 1,5 LD 210/200/1 1 200 20 1 280 39,2 2,1 35o 61,3 3,2 LD 210/400/1 1 400 80 3 500 125 4,6 600 180 6,6 LD 200/700/1 1 700 245 5,1 850 361,3 7,5 1000 500 10,4 LD 210/100/2 2 100 10 0,7 150 22,5 1,8 180 32,4 2,4 LD 210/200/2 2 200 40 1,6 300 90 3,6 380 144,4 5,8 LD 210/400/2 2 400 160 4,4 500 250 6,9 600 360 9,9 LD 210/700/2 2 700 490 8 850 722,5 11,7 1000 1000 16,2 LD 210/100/4 4 100 20 1,2 150 45 2,6 180 64,8 3,7 LD 210/200/4 4 200 80 2,5 300 180 5,7 380 288,8 9,1 LD 210/400/4 4 400 320 6,9 500 500 10,8 600 720 15,6 LD 210/700/4 4 700 980 12,4 850 1445 18,2 1000 2000 25,2 LD 210/100/8 8 100 40 1,7 150 90 3,9 180 129,6 5,6 LD 210/200/8 8 200 160 3,8 300 360 8,7 380 577,6 13,9 LD 210/400/8 8 400 640 10,7 500 1000 16,7 600 1440 24 LD 210/700/8 8 700 1960 19 850 2890 28 1000 4000 38,7 Dimensions in mm Type B [mm] H [mm] T [mm] Cooper [kg] Weight [g] LD 210/100/1 300 300 130 5,06 14 LD 210/200/1 400 400 180 12,32 21 LD 210/400/1 500 500 190 23,54 49 LD 200/700/1 500 500 330 53,79 75 LD 210/100/2 350 350 180 7,81 13 LD 210/200/2 400 400 220 18,92 29 LD 210/400/2 450 450 280 34,1 51 LD 210/700/2 550 550 420 83,6 107 LD 210/100/4 350 350 230 12,21 17 LD 210/200/4 420 420 290 29,37 43 LD 210/400/4 500 500 370 53,79 77 LD 210/700/4 600 600 540 129,8 160 LD 210/100/8 350 350 270 18,26 27 LD 210/200/8 450 450 350 44,99 60 LD 210/400/8 550 550 430 82,83 110 LD 210/700/8 650 650 680 199,1 240

Air choke LD 200

Air reactor with copper/disc winding Description Air reactors are used when a particularly high linearity is required. By its relatively simple structure, they are not only compact, but also very stable. With our expertise, REO air chokes maintain their full functionality even under extreme conditions. With our expertise, the REO air reactors perform to the required standard, even in the most arduous conditions. REO Mix & Match principle With REO Mix & Match you can choose from a wide range of of options – combine the various options in order to always get the best product for your application. REO is able to offer different designs and winding techniques, a variety of conductor materials and structures. Depending on the specific requirements, we are able to produce an optimal solution by combining these parameters to provide the perfect solution. Optional Layer winding/Disc winding Aluminium, Copper or aluminium + copper Protections: Paint coating, protective coating, housing or REO Xtreme Cooling fan/unit Sensors: Switch NO / NC, PT100, NTC, PTC Advantages No saturation Wide range of material selection Special protective coating High linearity L (i) Very good mechanical strength No hysteresis Optimal weight by forced air cooling Directional air flow through GRP conduits Very efficient liquid cooling option (waveguide) Able to be universally applied. Technical specification Frequency of the current: DC and AC Tolerances: + 10 / – 10 %, + 5 / – 5 % Taps: By default, no taps (available on request) Insulation: F or H Cooling method and cooling liquid according to IEC 60310: AN, AF or WF Test voltage: up to 12kV 60s 50Hz, up to 25kV 1,2/50µs Mounting: Suspended, vertical or horizontal Mechanical strength, mechanical simulation (FEM): EN 12663 Shock – and vibration stress: IEC 61373 Kat. 1 Kl. B Rated current: 100 – 700 A Type Inductance (mH) Cooling 3 m/s Cooling 5 m/s Cooling 8 m/s I [A] magn. Energy [J] P [kVA] at 20°C I [A] magn. Energy [J] P [kVA] at 20°C I [A] magn. Energy [J] P [kVA] at 20°C LD 200/100/1 1 100 5 0,4 140 9,8 0,7 180 16,2 1,2 LD 200/200/1 1 200 20 0,9 270 36,5 1,6 33o 54,5 2,4 LD 200/400/1 1 400 80 2,1 530 140,5 3,6 660 217,8 5,6 LD 200/700/1 1 700 245 3,4 850 361,3 5,6 1000 500 13,2 LD 200/100/2 2 100 10 0,7 130 16,9 1,6 150 22,5 1,4 LD 200/200/2 2 200 40 1,4 250 62,5 2,1 320 102,4 3,5 LD 200/400/2 2 400 160 3,3 500 250 5,1 600 360 7,3 LD 200/700/2 2 700 490 5,4 950 902,5 9,9 1100 1210 13,2 LD 200/100/4 4 100 20 1,1 120 28,8 1,6 140 39,2 2,2 LD 200/200/4 4 200 80 2,1 250 125 3,3 300 180 4,7 LD 200/400/4 4 400 320 5,1 500 500 7,9 600 720 11,4 LD 200/700/4 4 700 980 8,2 950 1805 15,1 1150 2645 22,1 LD 200/100/8 8 100 40 1,8 120 57,6 2,5 140 78,4 3,4 LD 200/200/8 8 200 160 3,3 250 250 5,2 300 360 7,5 LD 200/400/8 8 400 640 7,7 500 1000 12,1 600 1440 17,4 DIMENSIONS IN MM Type B (mm) H (mm) T (mm) Copper (kg) Weight (g) LD 200/100/1 300 300 110 11,1 15 LD 200/200/1 350 350 130 24,3 32 LD 200/400/1 420 420 185 57,2 68 LD 200/700/1 450 450 325 158,4 173 LD 200/100/2 300 300 120 12,5 17 LD 200/200/2 350 350 180 37,6 46 LD 200/400/2 400 400 270 90 103 LD 200/700/2 500 500 475 250,8 286 LD 200/100/4 300 300 170 19,7 26 LD 200/200/4 350 350 240 58,1 71 LD 200/400/4 420 420 360 140,6 157 LD 200/700/4 550 550 550 381,8 415 LD 200/100/8 300 300 200 31 40 LD 200/200/8 400 400 320 92,3 107 LD 200/400/8 500 500 365 214,5 235

Air chokes LD 120

Air reactor with copper/disc winding Description Air reactors are used when a particularly high linearity is required. By its relatively simple structure, they are not only compact, but also very stable. With our expertise, REO air chokes maintain their full functionality even under extreme conditions. With our expertise, the REO air reactors perform to the required standard, even in the most arduous conditions. REO Mix & Match principle With REO Mix & Match you can choose from a wide range of of options – combine the various options in order to always get the best product for your application. REO is able to offer different designs and winding techniques, a variety of conductor materials and structures. Depending on the specific requirements, we are able to produce an optimal solution by combining these parameters to provide the perfect solution. Optional Layer winding/Disc winding Aluminium, Copper or aluminium + copper Protections: Paint coating, protective coating, housing or REO Xtreme Cooling fan/unit Sensors: Switch NO / NC, PT100, NTC, PTC Advantages No saturation Wide range of material selection Special protective coating High linearity L (i) Very good mechanical strength No hysteresis Optimal weight by forced air cooling Directional air flow through GRP conduits Very efficient liquid cooling option (waveguide) Able to be universally applied. Technical specification Frequency of the current: DC and AC Tolerances: + 10 / – 10 %, + 5 / – 5 % Taps: By default, no taps (available on request) Insulation: F or H Cooling method and cooling liquid according to IEC 60310: AN, AF or WF Test voltage: up to 12kV 60s 50Hz, up to 25kV 1,2/50µs Mounting: Suspended, vertical or horizontal Mechanical strength, mechanical simulation (FEM): EN 12663 Shock – and vibration stress: IEC 61373 Kat. 1 Kl. B Rated Current: 200 – 1000A Type Inductance (mH) Cooling 3 m/s Cooling 5 m/s Cooling 8 m/s I [A] magn. Energy [J] P [kVA] at 20°C I [A] magn. Energy [J] P [kVA] at 20°C I [A] magn. Energy [J] P [kVA] at 20°C LD 120/200/0,2 0,2 200 4 0,4 240 5,8 0,6 285 8,1 0,8 LD 120/400/0,2 0,2 400 16 0,9 510 26 1,5 610 37,2 2,1 LD 120/700/0,2 0,2 700 49 1,3 860 74 2 1030 106,1 2,9 LD 120/1000/0,2 0,2 1000 100 2,2 1170 136,9 3 1400 196 4,2 LD 120/200/0,5 0,5 200 10 0,7 245 15 1 295 21,8 1,5 LD 120/400/0,5 0,5 400 40 1,6 510 65 2,5 600 90 3,5 LD 120/700/0,5 0,5 700 122,5 2,4 870 189,2 3,7 1030 265,2 5,2 LD 120/1000/0,5 0,5 1000 250 3,6 1200 360 5,1 1440 518,4 7,4 LD 120/200/1 1 200 20 1 255 32,5 1,6 300 45 2,2 LD 120/400/1 1 400 80 2,4 500 125 3,7 600 180 5,4 LD 120/700/1 1 700 245 3,7 870 378,5 5,8 1030 530,5 8,1 LD 120/1000/1 1 1000 500 5,5 1200 720 7,9 1420 1008,2 11,1 LD 120/200/2 2 200 40 1,6 250 62,5 2,4 300 90 3,5 LD 120/400/2 2 400 160 3,8 500 250 5,9 600 360 8,5 LD 120/700/2 2 700 490 5,8 870 756,9 8,9 1040 1081,6 12,7 LD 120/1000/2 2 1000 1000 8,5 1190 1416,1 12,1 1410 1988,1 17 LD 120/200/4 4 200 80 2,3 255 130,1 3,8 300 180 5,3 LD 120/400/4 4 400 320 6,3 500 500 9,8 600 720 14,1 LD 120/700/4 4 700 980 8,6 810 1312,2 13,4 1040 2163,2 19,1 LD 120/1000/4 4 1000 2000 12,7 1250 3125 19,9 1500 4500 28,7 LD 120/200/8 8 200 160 3,6 250 250 5,6 300 360 8,1 LD 120/400/8 8 400 640 9,3 500 1000 14,5 600 1440 20,8 LD 120/700/8 8 700 1960 13,5 870 3027,6 20,9 1050 4410 30,4 Dimensions in mm Type B [mm] H [mm] T [mm] Cooper [kg] Weight [g] LD 120/200/0,2 250 250 150 6,6 11 LD 120/400/0,2 350 350 180 16 25 LD 120/700/0,2 350 350 280 44,6 54 LD 120/1000/0,2 400 400 420 77,2 92 LD 120/200/0,5 300 300 180 11,9 18 LD 120/400/0,5 400 400 210 27,8 38 LD 120/700/0,5 400 400 350 80 93 LD 120/1000/0,5 500 500 360 127 147 LD 120/200/1 350 350 170 17,8 26 LD 120/400/1 450 450 240 39,1 57 LD 120/700/1 450 450 460 125 139 LD 120/1000/1 550 550 490 197 222 LD 120/200/2 400 400 190 26,9 37 LD 120/400/2 450 450 360 67,5 83 LD 120/700/2 450 450 580 192 217 LD 120/1000/2 550 550 640 305 341 LD 120/200/4 400 400 230 40,6 55 LD 120/400/4 450 450 530 109 129 LD 120/700/4 550 550 620 289 326 LD 120/1000/4 600 600 820 503 555 LD 120/200/8 450 450 320 64,1 81 LD 120/400/8 500 500 600 169 192 LD 120/700/8 550 550 830 453 506