REOLINE Laboratory Power Supplies (analog, separate windings)
Description
The laboratory variable transformers from the REOLINE Plus DC-SG/A series are equipped with an analog display, separate winding and continuously adjustable output voltage of 0..200 VDC. The absolute zero position results in a de-energized state at position 0.
Advantages
- Mains cable 2m long
- Illuminated power switch with integrated thermal short-circuit protection
- Toroidal variable-ratio transformer with absolute zero position
- Safety socket 4mm at the output
- Short time overload possible
- Easy connectivity
- Does not generate electromagnetic interference
- Modifications on request
- Residual ripple 48%
- Inrush-current limitation optional
Typical applications
- Laboratory
- Test field
- Workshop and service
Technical specification
Switching groupi0Max. Ambient temperature+ 40°C
Input voltage | 230 V |
Output voltage | 0-200 V |
Output current | 0,6 – 8 A |
Output power | 120 – 1600 W |
Frequency | 48% |
Protection | IP20 |
Produced in accordance with | IEC/EN 61558-2-4, IEC/EN 61558-2-13, IEC/EN 61010-1 |