Medical Technology
Inductive components for maximum quality and safety
Medical Technology
Particularly in medical technology, where the highest level of safety is a top priority, all products must undergo stringent testing.
The IEC 60601-1 and IEC 60601-1-2 standards define the safety of medical electrical equipment. Knowledge and a great deal of experience are required to implement these standards to ensure a safe power supply. All transformers are subjected to stringent tests in REO’s in-house test centre in Pfarrkirchen to ensure compliance with the relevant standards. In addition to the manufacture of standard products, REO has a large vertical range of manufacture. This makes it easy to realise customer-specific requirements, such as special housings or mounting plates for transformers. Thanks to our international subsidiaries and service partners, we ensure a very high availability of our medical technology and are where you need us for advice, planning and maintenance – on site at your premises.
Highlight of medical technology

REOMED
Isolating transformers for medical technology Ed. 3.2
REO has successfully completed certification in accordance with IEC 60601-1 (Edition 3.2) for its REOMED isolating transformers. This certification has been mandatory since October 2024 and underlines the quality and reliability of the REOMED series, which was specially developed for medical technology. The isolating transformers offer the highest levels of safety and reliability, which are essential for use in medical devices and systems. These transformers are used in a wide range of medical applications worldwide, from hospital equipment to complex medical imaging systems. The REOMED transformers are characterised by their excellent insulation capability and low electromagnetic interference, which ensures safe and reliable operation. One example of the products in this series is the REOMED 2200, which is unique with its rated output power of 2200 VA.
In addition, this isolating transformer offers improved voltage stability and optimised heat dissipation, resulting in an extended service life and increased operational safety. With the successful testing of the 3.2 Edition, REOMED isolating transformers are optimally prepared for and meet the current and future requirements of the market:
IEC60601-1:2005/AMD2:2020
ANSI/AAMI ES60601-1:2005/A2:2021
CAN/CSA C22.2 No. 60601-1:14/A2:2022-3 (medical technology) USA and Canada
IEC60601-1-2:2014(Partly); EN/IEC 61000-3-2:2014; EN/IEC 61000-3-3:2013
Lifesaver medical technology
Advantages
- REOMED with toroidal transformers
- Reduced energy costs, especially for continuous use
- Environmentally friendly due to lower energy consumption
- Integrated inrush current limiter
- Integrated short-circuit and overload protection
- Large selection of options
- Long service life