Passive Current Transformers Series IN-D

Differential current transformer Description The residual current transformer makes it possible to measure the residual current on single-phase or three-phase supply cables or individual lines. Both current-carrying conductors (forward and return conductors) are fed through the current opening of the current transformer. The current is measured by comparing the forward and return conductors. Any deviation is displayed at the output of the residual current transformer. Due to the use of highly permeable materials, a typical current deviation from 10 mA is given. The large opening allows the supply lines to pass directly through over a wide area, with the exception of the protective conductor. Due to the high current sensitivity, evaluation in several stages is possible: stage 1: Notice of a malfunction stage 2: Alarm stage 3: Switching off Advantages The measurement from 25 to 400 Hz Nanocrystalline core Transformer for measuring differential current High-quality UL-listed insulating materials (e.g., UL94VO) safe, electrically isolated primary and secondary circuits Robust housing designs (for horizontal/vertical mounting) Variable connections Wide range of housings with various push-through openings Residual current range 2 – 50 A Typical Applications Industry, Renewable energy sources, Metrology and testing techniquesEnergy, automation and building technology Technical data Type 2 4 8 29 30 40 30 40 50 Housing A Housing B Housing C Primary current [A] IPN 0,1 – 1 0,1 – 2 0,1 – 4 0,1 – 10 0,1 – 10 0,1 – 10 0,1 – 10 0,1 – 10 0,1 – 10 Max. Primary current [A] ImaxPN 2 4 8 20 30 40 30 40 50 Therm. Short-term current ITK 0,5 0,5 0,5 3,6 3,6 3,6 9 9 9 Secondary current [mA] IaN 2 4 4 20 10 5 20 16,67 10 Power [VA] Psek 0,004 0,008 0,016 0,030 0,030 0,015 0,06 0,05 0,06 Transformation ratio KN 500 500 1000 500 1000 2000 500 600 1000 Burden resistance [Ω] RB 1000 500 1000 75 300 600 150 180 600 Burden voltage [V] URB 2,0 2,0 4,0 1,5 3,0 3,0 3,0 3,0 6,0 Measuring accuracy 50 Hz [%] FU ≤ 1 ≤ 1 ≤ 1 ≤ 1 ≤ 1 ≤ 1 ≤ 1 ≤ 1 ≤ 1 Ambient temperature [°C] TA -10 to +50 -10 to +50 -10 to +50 -10 to +50 -10 to +50 -10 to +50 -10 to +50 -10 to +50 -10 to +50 Frequency range [Hz] f 25 to 400 25 to 400 25 to 400 25 to 400 25 to 400 25 to 400 25 to 400 25 to 400 25 to 400 Insulation test voltagePrimary / Secondary /2 sec [kVac] VP 3 3 3 3 3 3 3 3 3 Connection A Flat 6.3 x 0.8 / plug-in connectionMKS 1853 / terminal 1.5 mm² Storage temperature TS -25 to +85 -25 to +85 -25 to +85 -25 to +85 -25 to +85 -25 to +85 -25 to +85 -25 to +85 -25 to +85 Coil resistance RS 11 11 46 4,5 19 65 5,5 6,5 21 Weight m 0,068 0,068 0,070 0,278 0,278 0,290 0,280 0,280 0,290 Standards EN/IEC 61869-1/2 tracking resistance CTI Housing / cast resin 550/660M or 400/600M Creepage distance dCp 18 18 18 8 8 8 18 18 18 Clearance distance dCI 16 16 16 7 7 7 16 16 16 Dimensions in MM Type Housing PIN connection [mm²] h [mm] b1/b2 [mm] t [mm] DL/DL1 [mm] FS [mm] p/s [mm] a [mm] c [mm] f [mm] e [mm] l [mm] IN-D / 2 A 1 – 2 38 38/54 20 13 / – 6,3 x 0,8 – 30 47 4,8 – 9 IN-D / 4 A 1 – 2 38 38/54 20 13 / – 6,3 x 0,8 – 30 47 4,8 – 9 IN-D / 8 A 1 – 2 38 38/54 20 13 / – 6,3 x 0,8 – 30 47 4,8 – 9 IN-D / 20 B MKS1853 55 50/68 26 20,2 / – – 45 / 45 60 13 4,3 6 x 4,0 23 IN-D / 30 B MKS1853 55 50/68 26 20,2 / – – 45 / 45 60 13 4,3 6 x 4,0 23 IN-D / 40 B MKS1853 55 50/68 26 20,2 / – – 45 / 45 60 13 4,3 6 x 4,0 23 IN-D / 30 C Terminal 83 100/70 28 35 / 38 – 86 / – 14 – 7 – – IN-D / 40 C Terminal 83 100/70 28 35 / 38 – 86 / – 14 – 7 – – IN-D / 30 C Terminal 83 100/70 28 35 / 38 – 86 / – 14 – 7 – – Datasheet All data and configurations can be found in our product datasheet. Download Datasheet Certifications

Passive Current transformer Series IE (Pin Version)

Bushing-type current transformers (PIN version) Description In the case of bushing-type current transformers, the customer’s primary wire is pushed through the current transformer opening in the housing. The push-through opening depends on the size of the primary current. Wound primary type current transformers have a primary winding and a secondary winding. Both windings are applied on the closed toroidal core and are isolated from each other by insulation. This principle applies mainly where primary currents are small. Advantages PIN-Connection according to UL 94 V0 Bushing-type current transformers for direct conductor feedthrough Wound primary type current transformer, version for small currents Toroidal cores made of high-quality silicon-iron Measurement in the low-frequency range 16 2/3 to -400Hz High core output power and high-quality insulation (UL) circuits primaires et secondaires séparés électriquement des formes faciles à monter Variable connections, e.g. clamps, plugs, flat-cable plugs, flexible stranded wire or print mounting Wide range of housings with various push-through openings Technical specification Technical Data According to: EN/IEC 61869-1/2 Primary rated current: 1 – 50 A Frequency range: 50 – 400 Hz Type 1 3 5 10 25 50 2 Windings Through transformer Primary rated current [A] IPN 1 3 5 10 25 50 Max. Primary rated current [A] ImaxPN 1,2 3,6 6 12 30 60 Secondary current [mA] IaN 20 20 20 20 200 200 Power [VA] Psek 0,1 0,1 0,1 0,1 0,12 0,5 Ratio KN 50 150 250 500 1000 1000 Load resistance [Ω] RB 250 250 250 250 200 200 Load voltage [V] URB 5 5 5 5 5 10 Measuring accuracy 50 Hz [%] FU ≤ 1 ≤ 1 ≤ 1 ≤ 1 ≤ 1 ≤ 1 Ambient temperature [°C] TA -25 to + 70 -25 to + 70 -25 to + 70 -25 to + 70 -25 to + 70 -25 to + 70 Frequency range [Hz] f 50 – 400 50 – 400 50 – 400 50 – 400 50 – 400 50 – 400 Insulation test voltage [kVac] VP 3 3 3 3 3 3 Connection [mm²] 3-4/2-1 3-4/2-1 3-4/2-1 3-4/2-1 NC/2-1 NC/2-1 Weight [kg] 0,05 0,05 0,05 0,05 0,05 0,07 Standards EN/IEC 61869-1/2 Dimensions in mm Type PIN-connection [A] h [mm] b [mm] t [mm] DL [mm] s [mm] l [mm] a [mm] c [mm] IE/1 3-4/2-1 34 33 18 9 1,0 3,5 27,5 10 IE/3 3-4/2-1 34 33 18 9 1,0 3,5 27,5 10 IE/5 3-4/2-1 34 33 18 9 1,0 3,5 27,5 10 IE/10 3-4/2-1 34 33 18 9 1,0 3,5 27,5 10 IE/25 NC/2-1 34 33 18 9 1,0 3,5 27,5 10 IE/50 NC/2-1 38 38 20 13 1,0 6,5 30 10

Passive Current Transformer Series IB

Current transformers for printed-circuit boards Description REO current transformers series IB are suitable for mounting on printed-circuit boards in the electric range of modern drive engineering for control purposes and measurement value logging. All safety regulations as for example double insulation are obtained. Advantages Low space requirement Suitable for PCB mounting Conforms to UL 94 V0 Classe de précision 1 Mesure dans la gamme de fréquences 50-400Hz faible erreur de phase pour la mesure de la puissance très faibles pertes d’inversion magnétique et de courants de Foucault circuits primaires et secondaires séparés électriquement des formes faciles à monter Technical specification Type IB 0,5/5 IB 0,5/20 IB 0,5/40 Courant primaire [A] IPN 0 – 5 0 – 20 0 – 40 Max. Primary rated current [A] ImaxPN 7 25 50 Secondary current[mA] IaN 0 – 10 0 – 25 0 – 40 Performance [VA] Psec 0 – 0,010 0 – 0,025 0 – 0,040 Rapport de transmission KN 1:500 1:800 1:1000 Résistance de charge [Ω] RB 100 40 25 Tension de charge [V] URB 0 – 1 Précision de mesure 50 Hz [%] FU ≤ 1 Température ambiante [°C] TA 0..+85 Frequency range [Hz] f 50 – 400 Insulation test voltage [kVac] VP 3 Dimensions in mm Type Primary current [A] Height [mm] Width [mm] Depth [mm] Opening [mm] PIN strength [mm] PIN length [mm] IB 05/5 0 – 5 30 26,5/17,5 14,5 10,5 0,7×0,7 5,0 IB 05/20 0 – 20 30 26,5/17,5 14,5 10,5 0,7×0,7 5,0 IB 05/40 0 – 40 30 26,5/17,5 14,5 10,5 0,7×0,7 5,0 Data sheet Download our extensive catalog and discover many other REO products. Download Data sheet Certifications