Passive Current Transformer Series In-I

Pulse Current Transformers Description Due to the selected materials, REO pulse current transformers of the IN-I series can represent current with high accuracy and the corresponding transformation ratio – making them particularly suitable for power measurement, current monitoring and analysis, and for use in solar inverters. They are also ideally suited for use in active filters, as they can be designed for measuring current peaks. The primary current is measured via a current conductor that passes through the closed toroidal core. The magnetic field generated by the current flow through the conductor is absorbed by the toroidal core and, according to the transformation ratio of the secondary winding, generates a smaller current for measurement purposes. This method reduces a high measurement current to a significantly smaller current and additionally separates it from the primary circuit by means of safe galvanic isolation. Advantages Very precise current measurement Class 0.2 Pulse current measurement Low-loss core (core losses <10W/kg at 20kHz/200mT) Housing made of UL VO material (Conductor must be positioned) Diverse applications, e.g., for:Active filters, EMC measurements, and pulse current measurements Typical Applications Measurement and Testing Technology Technical data Type 50 100 200 Primary current [A] IPN r.m.s 0 – 50 0 – 100 0 – 200 Max. Primary current [A] ImaxPN r.m.s ± 60 ± 120 ± 240 Secondary current [mA] IaN r.m.s 0 – 50 0 – 100 0 – 200 Power [VA] Psek 0,5 1,0 1,5 Transformation ratio KN 1: 1000 1000 1000 Burden resistance [Ω] RB 200 100 37,5 Burden voltage [V] URB r.m.s 10 10 7,5 Measuring accuracy 50 Hz [%] FU ± 0.2 ± 0.2 ± 0.2 Ambient temperature [°C] TA -20 to +70 -20 to +70 -20 to +70 Frequency [Hz] f 0.050 to 50 0.050 to 50 0.050 to 50 Insulation test voltage Primary / Secondary / 2 sec [kVac] VP r.m.s 50 Hz 3 3 3 Storage temperature TS -25 to +85 -25 to +85 -25 to +85 Coil resistance RS @ TA = 25°C 11,5 11,5 9 Weight m 0,270 0,270 0,270 Standards EN/IEC 61869-1/2 Tracking resistance Housing / Casting resin 550 / 600M Creepage distance dCp 10 10 10 Clearance distance dCI 9 9 9 Datasheet All data and configurations can be found in our product datasheet. Download Datasheet Certifications

Passive Current Transformer Series IN-B

Bushing-type and bar-type current transformers DESCRIPTION For high requirements in railway and industrial technology at higher frequencies up to 50kHz. High-quality nanocrystalline core materials guarantee maximum transmission quality with low losses. Only UL-listed materials are used in full encapsulation with UL94-V0 material. Current transformers for increased requirements such as in the railway sector or mobile applications. Robust housing designs with reliable mounting options for vertical or horizontal installation. Advantages High reliability Non-critical in the event of overload currents Current transformers for precise current measurements Measurements in the frequency range 16 2/3 to -50kHz Use of nanocrystalline and high-quality cores High-quality wires in temperature class F (155°C), H (180°C) High-quality UL-listed insulating materials (e.g. UL94-V0) Safe electrically isolated primary and secondary circuits Robust housing designs (for horizontal/vertical mounting) Shock and vibration tests in accordance with DIN EN 61373Variable connections: clamps, plugs, flat-cable plugs or cablesWide range of housings with various push-through openings Typical applications Industry and Railway engineering Technical specification Primary rared current [A] IPN r.m.s 600 Max. Primary rated current [A] ImaxPN r.m.s 720 Secondary current [mA] IaN r.m.s 300 Power [VA] Psec 0,9 Ratio KN 1: 2000 Load resistance [Ω] RB 10 Voltage at load resistance [V] URB r.m.s 3 Measuring accuracy 50 Hz [%] FU @ IPN, TA = 25°C ≤ 1 Ambient temperature [°C] TA -25 to +70 Frequency [Hz] f 0,05 to 50 Insulation test voltagePrimary / Secondary / 2 sec [kVac] VP r.m.s 50 Hz 3 Connection 3×0,5mm² mit Schirm Cable Storage temperature [°C] -25 to +85 Secondary coil resistance [Ω] @ TA = 25°C 36,5 Weight [kg] 0,210 Standards EN61373 Data sheet Download our extensive catalog and discover many other REO products. Download Data sheet Certifications

Passive Current transformer Series IN

Instrument transformers DESCRIPTION The growing development and spread of electronic devices with high working frequencies require the use of current transformers with an extended frequency range.This demand can be met with specially selected materials in conjunction with optimized design. Advantages Litz wires or terminals according to UL 94 V-0 Current transformers for precise current measurements Higher accuracy classes 1; 0.5; 0.2 than with standard IE Measurements in the frequency range 16 2/3 to -50kHz Pulse measurement (e.g. 8/20μs) faible erreur de phase pour la mesure de la puissance Very low remagnetization losses and eddy current losses Use of nanocrystalline and high-quality cores circuits primaires et secondaires séparés électriquement des formes faciles à monter Wide range of housings with various push-through openings Technical specification Technical Data Primary rated current: 50 – 1.000 A Frequency range: 50 – 50.000 Hz Type 50 100 300 500 1000 Primary rated current [A] IPN 50 100 300 500 1000 Max. Primary rated current [A] ImaxPN 60 120 360 600 1200 Secondary current [mA] IaN 1000 1000 1000 1000 1000 Power [VA] Psek 0,5 1,0 2,5 5,0 15 Ratio KN 50 100 300 500 1000 Load resistance [Ω] RB 0,5 1,0 2,5 5,0 15 Load voltage [V] URB 0,5 1,0 2,5 5,0 15 Measuring accuracy 50 Hz [%] FU 1,0 1,0 1,0 1,0 1,0 Ambient temperature [°C] TA -25 to +70 -25 to +70 -25 to +70 -25 to +70 -25 to +70 Frequency range [Hz] f 0,05 to 50 0,05 to 50 0,05 to 50 0,05 to 50 0,05 to 50 Insulation test voltage [kVac] VP 3 3 3 3 3 Dimensions in mm Type Connection[mm²] h[mm] b1/b2[mm] t[mm] DL[mm] p/s[mm] a[mm] c1/c2[mm] f[mm] e[mm] l[mm] IE/50 2,5 70 70/89 33 31 57/57 77 15,5/… 4,3 6×4,3 25 IE/100 2,5 70 70/89 33 31 57/57 77 15,5/… 4,3 6×4,3 25 IE/300 2,5 95 94/110 44 40 78/78 100 18/… 5,3 8×5,3 25 IE/500 2,5 95 94/110 44 40 78/78 100 18/… 5,3 8×5,3 25 IE/1000 2,5 141 138/170 55 64 120/120 150 18/25 6,5 10×6,5 25 Data sheet Download our extensive catalog and discover many other REO products. Download Data sheet

Passive Current Transformer Series IE MODULAR

Closed-loop current transformers DESCRIPTION In the case of bushing-type current transformers, the customer’s primary wire is pushed through the current transformer opening in the housing. The push-through opening depends on the size of the primary current.Wound primary-type current transformers have a primary winding and a secondary winding. Both windings are applied on the closed toroidal core and are isolated from each other by insulation. This principle applies mainly where primary currents are small. Low-voltage current transformers for the proportional transformation of large currents to directly measurable smaller current values Advantages Bolts or flat plug connection Bushing-type current transformers for direct conductor feedthrough Toroidal cores made of high-quality magnetic cores Frequency range 16 2/3 to 400 Hz optional High core output power and high-quality insulation (UL) circuits primaires et secondaires séparés électriquement Easy-to-assemble modular-type housing Variable connections, e.g. bolts, flat plugs, litz wires Wide range of housings with various push-through openings Typical applications Industry, Renewable energy sources, Railway engineering, Energy, automation and building technology Technical specification Type IE modular 500 1000 2500 IPN Primary rated current 500 1000 2500 [A] ImaxPN Max. Primary rated current 600 1200 3000 [A] IaN Secondary current 1000 [mA] RB Load resistance 5 15 30 [Ω] URB Load voltage 5 15 30 [V] PSek Power 5 15 30 [VA] KN Transmission ratio 500 1000 2500 Fi Measuring accuracy(50 Hz) 0,5 0,5 0,5 [%] f Frequency 50-400 [Hz] TA Ambient temperature -25 bis +70 [°C] Vp Insulation test 3 [KVac] Connection MS bolt / flat pin 6.3 x 0.8 [mm²] Weight 0,8 0,8 1,8 [kg] Standards 61869-2 Dimensions in mm Type I [mm] h1/h2 [mm] t1/t2 [mm] s1/s2 [mm] b1/b2 [mm] D [mm] D1xD2 [mm] f [mm] e [mm] x1/x2 [mm] IE modular 500 70 76/35 38/64 57/57 57/50 30,2 30,4×10,4 4,3 4,3 36/15 IE modular 1000 94 100/47 42/72 78/78 78/60 38,5 40,5×13,5 5,3 5,3 36/15 IE modular 2500 135 141/67,5 52/88 102/102 102/70 57,5 60,5×20,5 6,5 6,5 36/15 Data sheet Download our extensive catalog and discover many other REO products. Download Data sheet

Passive Current Transformer Series Ie (Stranded Wire / Terminal)

Bushing-type current transformers Description In the case of bushing-type current transformers, the customer’s primary wire is pushed through the current transformer opening in the housing. The push-through opening depends on the size of the primary current. Wound primary type current transformers have a primary winding and a secondary winding. Both windings are applied on the closed toroidal core and are isolated from each other by insulation. This principle applies mainly where primary currents are small. Advantages Litz wires or terminals according to UL 94 V0 Bushing-type current transformers Wound primary type current transformer, version for small currents Toroidal cores made of high-quality silicon-iron Measurement in the low-frequency range 16 2/3 to -400Hz High core output power and high-quality insulation (UL) circuits primaires et secondaires séparés électriquement des formes faciles à monter Wide range of housings with various push-through openings UNIQUE SELLING POINT des formes faciles à monter Variable connections, e.g. clamps, plugs, flat-cable plugs, flexible stranded wire or print mounting Wide range of housings with various push-through openings Push-through openings Very long useful lifetime Typical applications Industry, Renewable energy sources, Railway engineering, Energy, automation and building technology Technical specification Type 50 100 300 500 1000 2000 3000 Primary rated current [A] IPN 50 100 300 500 1000 2000 3000 Max. Primary rated current [A] ImaxPN 60 120 360 600 1200 2400 3600 Secondary current [mA] IaN 1000 1000 1000 1000 1000 1000 1000 Power [VA] Psek 0,5 1,0 2,5 10 15 25 25 Ratio KN 50 100 300 500 1000 2000 3000 Load resistance [Ω] RB 0,5 1,0 2,5 10 15 25 25 Load voltage [V] URB 0,5 1,0 2,5 10 15 25 25 Measuring accuracy 50 Hz [%] FU 1,0 1,0 1,0 1,0 1,0 1,0 1,0 Ambient temperature [°C] TA -25 to + 70 -25 to + 70 -25 to + 70 -25 to + 70 -25 to + 70 -25 to + 70 -25 to + 70 Frequency range [Hz] f 50 to 400 50 to 400 50 to 400 50 to 400 50 to 400 50 to 400 50 to 400 Insulation test voltage [kVac] VP 3 3 3 3 3 3 3 Data sheet Download our extensive catalog and discover many other REO products. Download Data sheet Certifications

Active Current Transformer Series WKO-2C-B

Double core technology closed-loop current transformers for railway engineering Description The current transducer WKO-2C-B with hall effect elements and double-core technology has an extended frequency response of up to 150 kHz and an accurate phase response. The WKO-2C-B guarantees an increased current measurement accuracy of better than 0.3% in the whole frequency range: DC to 150 kHz. A completely redesigned electronics ensure that the new C/L current transducer has better drift compensation and an extended temperature range from -40°C to 85°C. Modular design The current transformer has a modular design and enables a wide range of mounting options. The cost-effective basic model consists of a housing with screw connections, cable entry and holes for mounting. The transformer can optionally be supplied with a mounting kit for busbars, Molex connectors and feet for horizontal or vertical mounting. According to EN 50178:1997 UL 94-V0 EN 50178 EN 50155:2007 IEC 61373:2010 Advantages Fulfils the required railway engineering safety standards: EN 50178, EN 50155:2007 and IEC 61373:2010 Shock- and vibration tested according to IEC 61373:2010 High current measurement accuracy of 0.3% Modular mounting plates providing universal mounting options Lower sensitivity to external magnetic fields Bidirectional and isolated current measurement up to ±750A current output Modular mounting plates REO double core technology All materials manufactured using UL-listed materials Technical specification Accuracy: better than 0.3% Ambient temperature: -40 ° C… + 85 ° C Storage temperature: -40 ° C… + 90 ° C Primary rated current: 300 – 2000 A Measurement range: 0… 4000 A Frequency range: 150000 Hz Type Primary RMS nominal current IPN [A] Measuring range IP [A] Supply UC [V] Measuring accuracy XG@Ipn [-20…70°C] fromIPN [%] Translation of [KN] Secondary RMS Nominal current ISN [mA] Secondary winding Resistance RS@85°C[Ω] No-load current [mA] WKO-2C-B-300 300 0…±2000 ±11,4…25,2 < ± 0,3 2000 150 13 26+IS WKO-2C-B-500 500 0…±1000 ±11,4…25,2 < ± 0,3 5000 100 76 26+IS WKO-2C-B-1000 1000 0…±2700 ±14,25…25,2 < ± 0,3 5000 200 42 26+IS WKO-2C-B-2000 2000 0…±4000 ±14,25…25,2 < ± 0,3 5000 400 26 26+IS ACCURACY AND DYNAMIC DATA Type Linearity error e [%] Offset error@25°C Io [mA] Offset Drift -25°C…+70°C IOT [mA] Response time tra[μs] Response time 10%-90% ta [μs] dl/dt [A/μs] Bandwidth -1 dB [kHz] WKO-2C-B-300 < ±0,1 ±0,5 < 25 0,2 0,4 400 150 WKO-2C-B-500 < ±0,1 ±0,5 < 25 0,2 0,4 400 150 WKO-2C-B-1000 < ±0,1 ±0,5 < 25 0,2 0,4 400 150 WKO-2C-B-2000 < ±0,1 ±0,5 < 25 0,2 0,4 1000 150 ISOLATION DATA Type Creepage distance dCp [mm] Air gap dCi [mm] tracking resistance [CTI] AC insulation test 50/60 Hz 1min Ud [kV] Pulse voltage test 1.2/50μs Ui [kV] Mass [kg] WKO-2C-B-300 14 13 600 6 12,5 0,340 WKO-2C-B-500 14 13 600 6 12,5 0,260 WKO-2C-B-1000 20 18 600 6 12,5 0,700 WKO-2C-B-2000 35 30 600 6 12,5 1,600 Dimensions in mm Type b1 [mm] b2 [mm] t [mm] s [mm] h [mm] D Ø [mm] D1/D2 [mm] Ø f[mm] Ø e[mm] WKO-2C-B-300 57 70 38 57 70 30,2 10,4/30,4 4,3 4,3 WKO-2C-B-500 57 70 38 57 70 30,2 10,4/30,4 4,3 4,3 WKO-2C-B-1000 78 94 42 78 94 38,5 13,5/40,5 5,3 5,3 WKO-2C-B-2000 102 135 52 102 135 57,5 20,5/60,5 6,5 6,5 Data sheet Download our extensive catalog and discover many other REO products. Download Data sheet Certifications

Active Current Transformer Series WKO-2C

Stromwandler

Double core technology closed-loop current transformers Description REO has developed a new generation of closed-loop (C/L) current transducers which guarantees increased current measurement accuracy better than 0.3% in the whole frequency range: DC to 150 kHz. The new current transducer type WKO-2C is a completely new development utilizing REO’s double-core technology magnetic design. The unit uses the latest Hall effect elements with an extended frequency response of up to 150 kHz and an accurate phase response. Completely redesigned electronics ensure that the new C/L current transducer has better drift compensation and an extended temperature range from -40°C to 85°C. Modular mounting plates providing universal mounting options All REO current transformers in the WKO-2C series work according to the proven compensation principle and are suitable for measuring direct and alternating currents. According to EN 50178:1997, UL 94-V0 EN50121, EN55011 IEC61869-1, IEC61869-8, IEC61010-1 According to: EN 50178:1997, UL 94-V0 Advantages High current measurement accuracy of 0.3% Modular mounting plates providing universal mounting options Lower sensitivity to external magnetic fields Bidirectional and isolated current measurement up to ±750A current output Modular mounting plates REO double core technology All materials manufactured using UL-listed materials Typical applications Power electronics: AC-DC motor control, inverter technology, drive control Railway technology: drive control Renewable energy: control and monitoring of wind turbines Technical specification Accuracy: better than 0.3% Ambient temperature: -40 ° C… + 85 ° C Storage temperature: -40 ° C… + 90 ° C Primary rated current: 300 – 2000 A Measurement range: 0… 4000 A Frequency range: 150000 Hz Type Primary RMS NominalcurrentIPN [A] Measurement rangeIP[A] Feed-inUC [V] Measurement accuracyXG@Ipn[-20…70°C]von IPN [%] RatioKN Secondary RMSNominal currentISN [mA] Secondary windingResistorRs@85°C [Ω] No-load current[mA] WKO-2C-300 300 0…±2000 ±11,4…25,2 >±0,3 2000 150 13 26+IS WKO-2C-500 500 0…±1000 ±11,4…25,2 >±0,3 5000 100 76 26+IS WKO-2C-1000 1000 0…±2700 ±14,25…25,2 >±0,3 5000 200 42 26+IS WKO-2C-2000 2000 0…±4000 ±14,25…25,2 >±0,3 5000 400 26 26+IS ACCURACY AND DYNAMIC DATA Type Linearity error e [%] Offset error@25°C IO [mA] Offset Drift -25°C…+70°C IOT [mA] Response time tRA [μs] Response time10%-90%ta [μs] dl/dt ta [A/μs] Bandwidth -1 dB [kHz] WKO-2C-300 < ±0,1 ±0,5 <25 0,2 0,4 400 150 WKO-2C-500 < ±0,1 ±0,5 <25 0,2 0,4 400 150 WKO-2C-1000 < ±0,1 ±0,5 <25 0,2 0,4 400 150 WKO-2C-2000 < ±0,1 ±0,5 <25 0,2 0,4 1000 150 ISOLATION DATA Type Creepage distance dCp [mm] Air gap dCi [mm] tracking resistance [CTI] AC insulation test 50/60Hz 1min Ud [kV] Pulse voltage test 1.2/50μs Ui [kV] Mass [kg] WKO-2C-300 14 13 600 6 12,5 0,340 WKO-2C-500 14 13 600 6 12,5 0,260 WKO-2C-1000 20 18 600 6 12,5 0,700 WKO-2C-2000 35 30 600 6 12,5 1,600 Mechanical data Type b1[mm] b2[mm] t[mm] s[mm] h[mm] D Ø[mm] D1/D2[mm] Ø f[mm] Ø e[mm] WKO-2C-300 57 70 38 57 70 30,2 10,4/30,4 4,3 4,3 WKO-2C-500 57 70 38 57 70 30,2 10,4/30,4 4,3 4,3 WKO-2C-1000 78 94 42 78 94 38,5 13,5/40,5 5,3 5,3 WKO-2C-2000 102 135 52 102 135 57,5 20,5/60,5 6,5 6,5 Data sheet Download our extensive catalog and discover many other REO products. Download Data sheet Certifications

Active Current Transformer Series WKO

Closed-loop current transformers Description Closed-loop current transformers The WKO current sensors work according to the proven compensation principle and are suitable for measuring direct, alternating and mixed currents. The primary current flow generates a magnetic flux, which is compensated by an internal secondary coil.The current evaluation is realized with an electronic circuit and a Hall sensor. The secondary compensation current is an exact reflection of the primary current to be measured. Unique Selling Point Measurement of direct, alternating and mixed currents Very high precision and short response time Broad frequency spectrum and low-temperature drift Very good linearity and overcurrent resistance No additional losses in the measuring circuit (DC to 150 kHz) Current output for lengthy transmission lines High-quality UL-listed insulating materials (e.g. UL94-V0) UNIQUE SELLING POINT Robust housing designs (for horizontal/vertical mounting) Variable connections, e.g. clamps, plugs, flat-cable plugs or cables Wide range of housings with various push-through openings Push-through openings Typical applications Industry, Renewable energy sources, Railway engineering, Energy, automation and building technology ELECTRICAL DATA Type WKO 25 WKO 50 WKO 100 WKO 300 WKO 500 WKO 1000 Primary RMS nominal current IPN [A] 25 50 100 300 500 1000 Measuring range IP [A] 0…±35 0…±70 0…±150 0…±500 0…±1000 0…±1500 Supply UC [V] ±12 …15 ±12 …15 ±12 …15 ±12 …15 ±12 …24 ±12 …24 Measuring accuracy XG@Ipn [-20…70°C] from IPN [%] > ±0,9 > ±1 > ±1 > ±1 > ±1 > ±1 Translation KN 1000 1000 1000 2000 5000 5000 Secondary RMS Nominal current ISN [mA] 25 50 100 150 100 200 Secondary winding Resistive sand RS@70°C [Ω] 16 43 24 30 72 48 Idle current [mA] 36+IS 11+IS 36+IS 36+IS 36+IS 24+IS ACCURACY AND DYNAMIC DATA Type WKO 25 WKO 50 WKO 100 WKO 300 WKO 500 WKO 1000 Linearity error e [%] < ±0,1 < ±0,1 < ±0,1 < ±0,1 < ±0,1 < ±0,1 Offset error@25°CIO [mA] > 0,3 > 0,3 > 0,4 > 0,2 > 0,2 > 0,3 Offset Drift-25°C…+70°CIOT [mA] > 0,5 > 0,5 > 1 > 0,5 > 0,5 > 0,5 Response time tra[μs] > 0,5 > 0,5 > 0,5 > 0,5 > 0,5 > 0,5 Response time 10%-90% ta [μs] > 1 > 1 > 1 > 1 > 1 > 1 dl/dt ta [A/μs] > 50 > 50 > 100 > 100 > 100 > 100 Bandwidth -1 dB [kHz] DC…150 DC…200 DC…100 DC…100 DC…100 DC…100 ISOLATION DATA Type WKO 25 WKO 50 WKO 100 WKO 300 WKO 500 WKO 1000 Creepage distance dCp [mm] 4 8 10 10 10 15 Air section dCi[mm] 3 7 9 9 9 12 Leakage current resistance [CTI] 600 600 600 600 600 600 AC insulation test 50/60Hz 1min Ud [kV] 3,8 3,8 3,8 3,8 6 6 Pulse voltage test 1,2/50μs Ui[kV] 6 6 6 6 12,5 14,5 Mass [kg] 0,08 0,022 0,125 0,125 0,240 0,450 Dimensions in mm Type Pin connection/ 4-pin h [mm] b [mm] b1/b2 [mm] t [mm] DL [mm] p/s [mm] a/a1 [mm] c1/c2 [mm] f [mm] e [mm] l [mm] WKO 25 A; -U; +U 39 39 – 26 10 – 2 x 10/6,5 25/6,5 M3 6,0 x 4,0 9 WKO 50 A; -U; +U Please find in the drawing WKO 100 A; -U; +U 55 – 55/68 26 20,2 45/45 – 13,0/– 4,3 6,0×4,0 12 WKO 300 A; -U; +U 55 – 55/68 26 20,2 45/45 – 13,0/– 4,3 6,0×4,0 12 WKO 500 A; -U; +U 70 – 70/89 33 31,0 57/57 – 15,2/– 4,3 6,0×4,3 12 WKO 1000 A; -U; +U 95 – 94/110 44 40,0 78/78 – 18,0/– 5,3 8,0×5,3 12 Data sheet Download our extensive catalog and discover many other REO products. Download Data sheet Certifications ​

Active Current Transformer Series WDI

AC/DC Open loop current transformers Description Open loop current transformers The WDI current sensor is an open-loop current transformer designed for measuring direct and alternating currents. The primary current generates a magnetic flux and this is evaluated by means of a magnetic circuit and Hall sensor in the air gap. The signal from the Hall sensor is processed by an electronic circuit and an exact representation of the primary current is output as a voltage. Advantages (electrical) Measurement of direct and alternating currents Voltage output Low power consumption No additional losses in the measuring circuit High-quality UL-listed insulating materials (e.g. UL94-V0 Safe electrically isolated primary and secondary circuits Good price/performance ratio Advantages (mechanical) Low weight Robust housing designs (for horizontal/vertical mounting) Connections: clamps, plugs, flat-cable plugs or cables Wide range of housings with various push-through openings Typical applications Industry, Renewable energy sources, Railway engineering, Energy, automation and building technology Technical specification Type 25 150 300 Primary rated current [A] ÎPN Peak 25 150 300 Max. Primary rated current [A] ÎmaxPN Peak 0- ± 30 0- ± 180 0- ± 360 Secondary current [mA] ÎoutPN ± 5 ± 5 ± 5 Min. Load resistance RBmin ± 15 Vdc ± 30A peak=2 ± 150 peak=2 ± 300 peak=2 . . . ± 180A peak=2 ± 360A peak=2 Max. Load resistance RBmax ± 15 Vdc ± 30A peak=10 ± 150 peak=2 ± 300 peak=2 . . . ± 180A peak=2 ± 360A peak=2 Max. Peak output voltage [V] ÜaN Peak ± 10 ± 10 ± 10 Operating voltage [Vdc] US ± 5% ± 15 ± 15 ± 15 No-load current [mA] IBO (@ ± 15 V) + loutpN 9 9 9 Insulation test voltage[kV] VP r.m.s. 50 Hz 3 3 3 Standing impulse voltage [kV] VW 1,2/50μs 3 5 5 Measuring accuracy 50 Hz [%] FU @IPN, TA=25°C ± 0,6 ± 0,6 ± 0,6 Linearity error [%] FLU @TA=25°C ≤ 1,0 ≤ 1,0 ≤ 1,0 Offset voltage [mV] Uo @IPN = 0, TA = 25°C 20 20 20 Drift offset voltage [mV] △Uo Io -25°C…+70°C 60 60 60 Temperature drift [%K] %/△T ≤ 0,05 ≤ 0,05 ≤ 0,05 Response time [μs] tr @ 90% von IPN < 25 < 25 < 25 Frequency range [kHz] f (-3 dB) DC … 10 (-3 dB) DC … 10 (-3 dB) DC … 10 Ambient temperature [°C] TA -25 to + 75 -25 to + 75 -25 to + 75 Storage temperature [°C] Ts -10 to + 85 -10 to + 85 -10 to + 85 Weight [kg] m 0,075 0,075 0,075 Creepage distance [mm] dCp 4 10 10 Air section [mm] dCpi 3 9 9 Dimensions in mm Type PIN-Conncetion / 4-pole h [mm] b [mm] b1/b2 [mm] t [mm] DL [mm] p/s [mm] a/a1 [mm] c1/c2 [mm] f [mm] e [mm] l [mm] WDI 25 A; O,-U; +U 39 39 – 26,5 10 – 3 x 10/6,5 25/6,5 M4 – 9 WDI 150 A; O,-U; +U 55 – 55/68 26 20,2 45/45 60/– 13/– 4,3 6,0 x 4,0 23 WDI 300 A; O,-U; +U 55 – 55/68 26 20,2 45/45 60/– 13/– 4,3 6,0 x 4,0 23 Data sheet Download our extensive catalog and discover many other REO products. Download Data sheet Certifications