Programmable Phase Angle Controller REOVIB MTS 441

IP54 or IP20 DESCRIPTION The REOVIB MTS series includes single-channel, two-channel and three-channel control units for vibratory conveyor drives. These are phase-angle control systems. The vibration frequency of the conveyor can be the same as or twice the frequency of the input voltage. (Other frequencies are possible depending on the type). Plug and socket connections for all inputs and outputs make rapid installation possible and facilitate the combination of several devices with each other or with external control systems. The devices use digital technology and are operated via a LED or LCD display and buttons. All settings can be made without the housing having to be opened. The REOVIB MTS 441 control units have a setpoint adjustment option for the conveying speed. All parameters can be entered via the display integrated in the front panel. The MTS 441 can be linked to other devices from the REOVIB MTS series. User-specific settings can be saved and recalled. The REOVIB MTS 441 is available in IP20 and IP54 versions, as well as in various connection variants: Input cable/output socket Complete cable connection solution for mains, output and control connections ADVANTAGES Phase-angle control with programmable functions Single-channel, two-channel or three-channel control for the optimal control of the complete conveyor system Digital setting of all parameters via LED display or multiline LCD display (MTS 443 LCD) In IP54 or IP20 design (MTS 441) Automatic mains voltage adjustment Material flow control Various sensor logic functions can be set Adjustable soft start With fill level/overflow control Integrated mains voltage compensation with constant vibration amplitude TECHNICAL SPECIFICATION Mains input 110/ 230 V autom. recognition Mains frequency 50 / 60 Hz +/- 3 Hz Output voltage 20 … 100V/ 40…210 V Output current max. 6 A, max. 10 A (Option) Number of outputs 1 Max. Output current from all outputs – Vibration frequency 50 … 100 Hz (60/120 Hz) Setpoint value Display, P0ti, 0 … 10 V, 0 (4) … 20 mA Status signal 24 V DC Ext. Enable 24 V DC, Switch Sensor supply 24 V DC Setting Umin/ Umax Display Soft start Adjustable 0…5 Sec. Fill level/ overflow control PNP, 24 V DC Mains voltage compensation ✓ Coarse-/fine control ✓ Selectable cycle operation ✓ Sensor time out control ✓ Conformity CE, RoHS Protection class IP20/ IP54 Data sheet Download our extensive catalog and discover many other REO products. Download Datenblatt Zertifizierung
Phase angle control REOVIB RTS SYSTEM

IP00, switch cabinet mounting DESCRIPTION Basic module RTS SYSTEM In open design for mounting on a DIN rail with an output channel of max. 6 A with fill level control/level switch and mains voltage compensation. The basic module has a power supply for expansion modules. This means that additional output modules can be added up to a total current of 10 A. RTS SYSTEM extension module In open design for mounting on a DIN rail. The extension module has an output channel max. 6 A with level control/level switch and mains voltage compensation and can be installed together with the basic module and several extension modules. REOVIB RTS SINGLE In open design for mounting on a DIN rail with an output channel of max. 6 A, level control/level switch and mains voltage compensation. ADVANTAGES Cost-effective phase control units with protection class IP00 for control cabinet installation Can be used as a standalone device or in modular design for control of a complete feed system Output current up to 6A Versions available with fill level/overflow control Mains voltage compensation with constant amplitude Adjustable soft start ramp time TYPICAL APPLICATIONS Conveyor & assembly automation, conveyor technology, sieving technology TECHNICAL SPECIFICATION RTS Single RTS basic module RTS extension module Mains input 110/ 230V switchable 110/ 230V switchable via RTS basic module Mains frequency 50 / 60 Hz +/- 3 Hz 50 / 60 Hz +/- 3 Hz via RTS basic module Output voltage 20 … 100V/40…210 V 20 … 100V/40…210 V 20 … 100V/40…210 V Output current max. 6 A max. 6 A max. 6 A Vibration frequency 50 … 100 Hz(60/120Hz) 50 … 100 Hz(60/120Hz) 50 … 100 Hz(60/120Hz) Setpoint specification P0ti, 0 … 10 V, 0 … 20 mA P0ti, 0 … 10 V, 0 … 20 mA P0ti, 0 … 10 V, 0 … 20 mA Ext. Enable 24 V DC, Switch 24 V DC, Switch 24 V DC, Switch Umin/ Umax internal potentiometers internal potentiometers internal potentiometers Soft start adjustable 0.2…5 sec. adjustable 0.2…5 sec. adjustable 0.2…5 sec. Max. Output current from all outputs – 15 A – Mains voltage compensation ✓ ✓ ✓ Fill level control/ congestion control ✓ ✓ ✓ Conformity CE, RoHS CE, RoHS CE, RoHS Protection class IP00 IP00 IP00 Data sheet Download our extensive catalog and discover many other REO products. Download Datenblatt Zertifizierung
Phase Angle Controller REOVIB RTS RS6/539

IP54 design for mounting directly on the vibrating machine, single output DESCRIPTION The devices in the REOVIB RTS series are available as a housing variant with protection class IP54 for direct installation on the system. The maximum output current is 6 A. The devices have a compensation circuit for constant oscillation amplitude in the event of mains voltage fluctuations, potentiometers for setting the Umin / Umax and the soft start time as well as a level control/back-up circuit. (Devices with level control/back-up circuit contain a back-up relay for linking with other control devices). The control units are available in different versions: Input cable/output cable Input cable/output socket Complete cable connection solution for mains, output and control connections(For REOVIB RTS RS6/539-559). ADVANTAGES Versions available with fill level/overflow control Inexpensive phase angle controls with extended functionalities IP54 design for mounting directly on the vibrating machine Output current up to 6A Mains voltage compensation with constant amplitude Adjustable soft start ramp time TYPICAL APPLICATIONS Conveyor & assembly automation, conveyor technology, sieving technology TECHNICAL SPECIFICATION RTS R6/539 RTS RS6/539-559 Mains input 110/ 230 V switchable 110/ 230 V switchable Mains frequency 50 / 60 Hz +/- 3 Hz 50 / 60 Hz +/- 3 Hz Output voltage 20 … 100V/ 40…210 V 20 … 100V/ 40…210 V Output current max. 6 A max. 6 A Vibration frequency 50 … 100 Hz(60/120 Hz) 50 … 100 Hz(60/120 Hz) Setpoint specification Potentiometer, 0 … 10 V, 0 … 20 mA Potentiometer, 0 … 10 V, 0 … 20 mA Ext. Enable 24 V DC, Switch 24 V DC, Switch Umin/ Umax internal potentiometers internal potentiometers Soft start adjustable 0.2…5 sec. adjustable 0.2…5 sec. Status relay optional ✓ Mains voltage compensation ✓ ✓ Fill level control/ congestion control – ✓ Conformity CE, RoHS CE, RoHS Protection class IP54 IP54 *For IP54 Data sheet Download our extensive catalog and discover many other REO products. Download Datenblatt Zertifizierung
Phase Angle Controller REOVIB RTS R6/539

IP54 design for mounting directly on the vibrating machine, single output Description The devices in the REOVIB RTS series are available as a housing variant with protection class IP54 for direct installation on the system. The maximum output current is 6 A. The devices have a compensation circuit for constant amplitude in the event of mains voltage fluctuations, potentiometers for setting Umin / Umax and the soft start time. (Devices with fill level control / back-up circuit include a back-up relay for linking to other control devices). The control units are available in different versions: Input cable/output cable Input cable/output socket Advantages Inexpensive phase angle controls with extended functionalities IP54 design for mounting directly on the vibrating machine Output current up to 6A Versions with level control / accumulation circuit available (REOVIB RTS RS6/539-559) Mains voltage compensation with constant amplitude Adjustable soft start ramp time Typical applications Conveyor & assembly automation, conveyor technology, sieving technology Technical specification Mains input 110/ 230 V switchable 110/ 230 V switchable Mains frequency 50 / 60 Hz +/- 3 Hz 50 / 60 Hz +/- 3 Hz Output voltage 20 … 100V/40…210 V 20 … 100V/40…210 V Output current max. 6 A max. 6 A Vibration frequency 50 … 100 Hz(60/120Hz) 50 … 100 Hz(60/120Hz) Setpoint specification P0ti, 0 … 10 V, 0 … 20 mA P0ti, 0 … 10 V, 0 … 20 mA Ext. Enable 24 V DC, Switch 24 V DC, Switch Umin/ Umax setting Internal potentiometers internal potentiometers Soft start adjustable 0.2…5 sec. adjustable 0.2…5 sec. Status relay optional ✓ Mains voltage compensation ✓ ✓ Fill level control/ congestion control – ✓ Conformity CE, RoHS CE, RoHS Protection class IP54 IP54 *For IP54 Data sheet Download our extensive catalog and discover many other REO products. Download Data sheet Zertifizierung />
REOVIB SMART IP20

IP20 Description The REOVIB SMART series includes phase angle control units for use in vibratory conveyor applications. The devices offer the most important functions for use in vibratory conveyor technology and therefore represent a cost-effective option for controlling vibratory conveyors – and in a high-quality design. The devices are available in various protection classes – as a control cabinet installation module in IP20 or as a housing variant in IP54 for direct mounting on the application. The housing variants with protection class IP54 are available in different versions: Input cable/output cable Input cable/output socket Complete cable connection solution for mains, output and control connections REOVIB SMART ATS 100 devices are available in an IP54 housing with output currents up to 15 A and are listed by UL. Advantages Cost-effective phase-angle control systems with vital functionality IP54-Version for mounting directly on the vibrating machine or IP20-Version fas a module for mounting in a switch cabinet Versions available with UL approval (SMART ATS 100) Output current up to 15 A Typical applications Conveyor & assembly automation, conveyor technology, sorting systems Technical specification Mains input 110/ 230 V switchable Mains frequency 50 / 60 Hz +/- 3 Hz Output voltage 20 … 100V/ 40…210 V Output current max. 15 A Vibration frequency 50Hz 50 … 100 Hz Vibration frequency 60Hz 60 … 120 Hz Setpoint value P0ti, 0 … 10 V, 0… 20 mA Ext. Enable 24 V DC, Switch Sensor supply 24 V DC Setting Umin/ Umax Internal potentiometer Soft start fixed Mains voltage compensation – Conformity UL,CE, RoHS Protection class IP54 Ambient temperature 0…45°C Zertifizierung Optional UL-certified
REOVIB SMART System phase-angle gates

In an open design for mounting on a DIN rail with an output channel of max. 6 A with level control/level switch.
REOMED Isonet Network Isolator

Accessories DESCRIPTION The REOMED Isonet network isolator is used for galvanic isolation of devices in copper cable-based Ethernet networks The separation protects the device and people from the effects of possible electrical voltage peaks on the network cables. Potential equalisation currents via the network cable shielding are reliably prevented. ADVANTAGES Protection in both transfer directions Interruption of the shield connection of the network cable No additional power supply required No software installation required Maintenance-free RoHS compliant EN 60950-1 EN 60601-1 TECHNICAL SPECIFICATION Isolation voltage 4 kV Input/ Output connector RJ45 Supported network protocols 10BaseT, 100BaseTx, 1000BaseT Insertion loss -1,3 max dB Return loss -8 min. dB Protection rating IP 20 Max. voltage of the connected devices 250 Vac ms Operating temperature -10 to +70 °C Storage temperature -40 bis +85 °C Air humidity 10 to 90 % (without condensation) Gehäuse Kunststoff Weight 45 g Dimensions [H x B x T] 25 x 66 x 40 mm Data sheet Download Datenblatt Certifications
REOMED ISOMONITOR

Accessories DESCRIPTION Conventional protective measures against isolation faults, such as fault current circuit breaks for home installations, may not recognise potential isolation faults on the output side when isolation transformers are used. The ISOMONITOR monitors the dielectric resistances of both live contacts of the isolation transformer’s output socket against grounding potential and generates a warning signal in the event of a fault.Isolation resistance is monitored in case the threshold value of 50 kΩ (25 kΩ) is exceeded. If this value is exceeded, both an acoustic signal (a pulsating tone of approx. 3 kHz, approx. 98 db) and a visual signal (LED indicator) are generated. The ISOMONITOR can be directly connected to one of the output sockets on the isolation transformer. Other optional functions are monitoring the transformer temperature with aural and visual alarms, and a visual display of the transformer’s power consumption.In the event of a fault, the aural alarm can be reset with an acknowledgement button, and the visual alarm is automatically reset as soon as the fault has been dealt with. Should a function test be performed with the ISOMONITOR, an appropriate test plug (adapter cable required) for simulating an isolation fault must be plugged into one of the output sockets on the isolation transformer. The signal will be triggered while the test plug is plugged in. ADVANTAGES IEC 60601-1-2:2014 Easy to operate Aural and visual signals Function test with test plug Power consumption display (optional) Temperature warning (optional) TECHNICAL SPECIFICATIONS Mains voltage 230 115 (V) Working range 200 – 240 100 -120 (VAC) Threshold value ≤ 50 ≤ 25 (kΩ) Response Time < 2 < 2 (sec.) Signal Display In operation: LED green (Power on) Insulation failure: LED yellow (Insulation) Transformer limit temperature reached: LED yellow (temperature) Transformer power load (Power): LED green: 30 % LED yellow: 60 % LED red: 90 % Acoustic signal For insulation warning: pulsating continuousAt overtemperature: Continuous tone Ambient operating temperature 0… +40 (°C) relative ambient operating humidity 30… 75 (%) Protection class II Type of protection IP 20 Size [H x B x T] 192 x 34 x 56 (mm) Data sheet All data and configurations can be found in our product data sheet. Download datasheet Certifications